Precision Cooling for Hot Climates

The high-temperature environment in hot climate regions presents severe challenges for the efficient, energy-saving, and stable operation of data centers. ATTOM brings a new series of precision air conditioning system is specifically designed for use in high-temperature environments.

TALK TO MMC

Plan your next step with our team

Share your requirements, location and timeline. We��ll help you define a suitable solution and delivery scope.

[email protected]
Talk to our team

Precision Cooling for Hot Climates enquiry. We reply within one business day.

Or call +92 311 1555053

55℃Ambient temperature
R134AZero ODP · GWP 1430
1.5 – 30 kWSmoothAir modular
5.6 – 200 kWWiseAir room
Optimized Design up to 55C Ambient

Optimized Design up to 55C Ambient

The optimized refrigeration system uses R134A, ensuring stable operation at temperatures up to 55°C with high reliability. We offer a comprehensive range of air conditioning types, including rack-mounted, wall-mounted, top-mounted, row-mounted, and room air conditioning, to meet both current and future IT requirements.

Suited for
Hot climate region in AfricaMiddle EastAsiaEuropeAmerica

Product Features & Technical Specifications

Atom Precision Cooling Platform: SmoothAir™ Modular Precision Cooling (1.5kW - 30kW), specially designed and optimized for Modular Data Centers, and WiseAir™ Room Precision Cooling (5.6kW - 200kW), highly reliable computer room air conditioner solutions.

SmoothAir™ – Wall Mount Package DX

SmoothAir™ – Wall Mount Package DX

1.5kW - 31.5kW

Air cooled, wall mount, indoor and outdoor package, suitable for micro data center, mini modular data center solutions.

  1. Industry top brand compressor. Highly reliable and efficient.
  2. Precision cooling controller monitors and protects unit constantly. Easy to be integrated into BMS to display, control and manage the system.
  3. Adopts high pressure/high air flow centrifugal blower suiting critical equipment cooling condition.
  4. Packaged design easy for installation, service and shipping.
  5. Wall mounting to side of cabinet no occupying of IT space.
  6. Green refrigerant is highly efficient and no ODP.
Request pricing →
SmoothAir™ – Top Mount Package DX

SmoothAir™ – Top Mount Package DX

5.5kW - 31.5kW

Air cooled, Top mount, indoor and outdoor package, suitable for Container data center solutions.

  1. Industry top brand compressor. Highly reliable and efficient.
  2. Precision cooling controller monitors and protects unit constantly. Easy to be integrated into BMS to display, control and manage the system.
  3. Adopts high pressure/high air flow centrifugal blower suiting critical equipment cooling condition.
  4. Packaged design easy for installation, service and shipping.
  5. Top mounting to the container, no occupying of IT space.
  6. Green refrigerant is highly efficient and no ODP.
Request pricing →
SmoothAir™ – Row Mount DX

SmoothAir™ – Row Mount DX

5.6kW – 90.1kW · 300mm 600mm Width

Air cooled, row mount, split type, ideal for micro data center, integrated modular data center solutions.

  1. Dynamically modulated cooling capacity with inverter compressor maintains temperature within envelop and prevent compressor from cycling during low heat load period.
  2. Air flow modulates with EC fans to match IT requirements. Each fan module is easy to change with quick couple connections.
  3. Precision cooling controller monitors and protects unit constantly. Easy to be integrated into BMS to display, control and manage the system.
  4. R410A green refrigerant is highly efficient and no ODP.
  5. Copper piping adopts quick connections and supports bottom and top connections.
  6. Easy to change G4 air filter and sealed doors help to build a clean and quiet MDC.
  7. Slide drawer style electric box makes service easier.
  8. Optional with condensate pump, water leaking kit and long piping kit for diverse applications.
Request pricing →
WiseAir™ – Room Cooling DX Air Cooled

WiseAir™ – Room Cooling DX Air Cooled

5.6kW - 52.5kW

Highly reliable computer room air conditioner solutions.

  1. Highly reliable scroll compressor.
  2. Industry leading brands EC fan.
  3. Intelligent industry-leading controller with color touch screen. Supports BMS integration, teamwork and master/slave working policy.
  4. A large area of high-efficiency heat exchanger.
  5. Industry-leading brands thermostatic expansion valve/electronic expansion valve.
  6. A large area air filtration system closed to heat exchanger.
  7. Highly efficient electrode humidifier.
  8. Modular design of cabinet can easily achieve secondary disassembly.
Request pricing →

Optimized Refrigeration System

  • Refrigeration system of hot climate optimized, using R134A to be working at 55C ambient temperature with high reliability.
  • Green refrigerant R134A with lower working pressure, zero ODP(ozone depletion potential) effect, and lower GWP(global warming potential) value.
Optimized Refrigeration System

Green Energy Efficiency

  • Top level components from leading brands and unique design assure high reliability of products.
  • Inverter compressor and EC fan with intelligent control system ensure precise temperature control.
  • Fully compatible with hot and cold aisle systems to provide an efficient cooling environment.
  • Green refrigerant R134A no ODP effect.
Green Energy Efficiency

Advanced Controller with Smart Function

Insightful Sensor Data

Insightful Sensor Data

  • Full sensors of Refrigeration System deep insight into working status of system.
  • Easy remote debug and support to customer with confidence.
  • No need bring pressure gauge during service and installations.
  • Supports further advanced analysis with full perspective system data.
Builtin Teamwork Function

Builtin Teamwork Function

  • Built in Teamwork function, supports master/standby working, and scheduled rotation.
  • Group 8 units as standard, maximum 200 units customization.
  • RJ45 network cable connection no extra hardware.
  • Supports master control mode by following master unit logic.
Rich Remote Access Portal

Rich Remote Access Portal

  • Built in web page supports remote by browser.
  • Support Modbus-RTU protocol by standard.
  • Support SNMP, Email, Modbus-TCP, BAC-Net, IPV6 for remote monitoring by system.

Key Components

Top level highly reliable components: Hitachi, Ziehl-Abegg, Carel, Schneider Electric and Belimo.

Inverter Compressor

Inverter Compressor

  • Capacity adjustable 30%-100%.
  • Stable working and improved compressor life by Modulating compressor speed.
  • No on/off brush working mode.
  • Green refrigerant R134A no ODP effect.
EC Fans

EC Fans

  • Best in class design and reliability.
  • Highest efficiency EC Fan system.
  • Speed adjustable 0%-100%.
  • Direct drive system no belts easier replacement and service.
  • Higher external static flexible for special application.
Electronic Expansion Valve

Electronic Expansion Valve

  • Automatically modulating refrigerant flow per system requirement.
  • Better COP performance during low temperature season comparing TEV system.
  • Better refrigerant flow feeding during compressor startup, to reach higher reliability of compressor working.

Technical data

Technical data from the ATTOM product brochure.

Wall Mount Package DX

ModelS-001WAS-002WAS-005WAS-007WAS-012WAS-017WAS-020WAS-025WAS-030WA
Mount typeWallWallWallWallWallWallWallWallWall
Cooling typeInverter DXInverter DXInverter DXInverter DXInverter DXInverter DXInverter DXInverter DXInverter DX
RefrigerantR134AR134AR134AR134AR134AR134AR134AR134AR134A
Total cooling (kW)1.52.05.57.512.517.521.225.131.5
SHR (%)100100100100100100100100100
Air volume (m³/h)3806501850200024003500400051006300
Fan typeACACECECECECECECEC
Reheating (kW)--3.03.03.06.06.06.06.0
Heater type--PTCPTCPTCPTCPTCPTCPTC
Humidification (kg/h)--1.51.51.51.51.51.53
Humidifier type--ElectrodeElectrodeElectrodeElectrodeElectrodeElectrodeElectrode
Height (mm)7467461920192021002100210021002100
Depth (mm)200200650650650650650650650
Width (mm)44644690090010001000100013501350
Weight (kg)3435180230285320355395415
Power input ①208-240V/50-60Hz/1-2Ph208-240V/50-60Hz/1-2Ph208-240V/50-60Hz/1-2Ph208-240V/50-60Hz/1-2Ph208V/60Hz/3Ph208V/60Hz/3Ph208V/60Hz/3Ph208V/60Hz/3Ph208V/60Hz/3Ph
FLA ①, cooling only (A)2.93.912.213.317.228.729.736.744.0
FLA ①, with heater & hum. (A)--25.926.925.445.346.354.262.0
Power input ②380-415V/50-60Hz/3Ph380-415V/50-60Hz/3Ph380-415V/50-60Hz/3Ph380-415V/50-60Hz/3Ph380-415V/50-60Hz/3Ph380-415V/50-60Hz/3Ph380-415V/50-60Hz/3Ph380-415V/50-60Hz/3Ph380-415V/50-60Hz/3Ph
FLA ②, cooling only (A)----11.017.818.423.027.3
FLA ②, with heater & hum. (A)----15.526.827.532.136.4
Power input ③460V/60Hz/3Ph460V/60Hz/3Ph460V/60Hz/3Ph460V/60Hz/3Ph460V/60Hz/3Ph460V/60Hz/3Ph460V/60Hz/3Ph460V/60Hz/3Ph460V/60Hz/3Ph
FLA ③, cooling only (A)----9.615.315.820.023.5
FLA ③, with heater & hum. (A)----13.322.823.327.531.0

Top Mount Package DX

ModelS-005TAS-007TAS-012TAS-017TAS-020TAS-025TAS-030TA
Mount typeTopTopTopTopTopTopTop
Cooling typeInverter DXInverter DXInverter DXInverter DXInverter DXInverter DXInverter DX
RefrigerantR134AR134AR134AR134AR134AR134AR134A
Total cooling (kW)5.57.512.517.521.225.131.5
SHR (%)100100100100100100100
Air volume (m³/h)1850200024003500400051006300
Fan typeECECECECECECEC
Reheating (kW)3.03.03.06.06.06.06.0
Heater typePTCPTCPTCPTCPTCPTCPTC
Humidification (kg/h)1.51.51.51.51.51.53
Humidifier typeElectrodeElectrodeElectrodeElectrodeElectrodeElectrodeElectrode
Height (mm)650650850850850850850
Length (mm)2000200020002000200020002000
Width (mm)60060010001000100012001200
Weight (kg)180230285320355395415
Power input ①208-240V/50-60Hz/1-2Ph208-240V/50-60Hz/1-2Ph208V/60Hz/3Ph208V/60Hz/3Ph208V/60Hz/3Ph208V/60Hz/3Ph208V/60Hz/3Ph
FLA ①, cooling only (A)12.213.317.228.729.736.744.0
FLA ①, with heater & hum. (A)25.926.925.445.346.354.262.0
Power input ②380-415V/50-60Hz/3Ph380-415V/50-60Hz/3Ph380-415V/50-60Hz/3Ph380-415V/50-60Hz/3Ph380-415V/50-60Hz/3Ph380-415V/50-60Hz/3Ph380-415V/50-60Hz/3Ph
FLA ②, cooling only (A)--11.017.818.423.027.3
FLA ②, with heater & hum. (A)--15.526.827.532.136.4
Power input ③460V/60Hz/3Ph460V/60Hz/3Ph460V/60Hz/3Ph460V/60Hz/3Ph460V/60Hz/3Ph460V/60Hz/3Ph460V/60Hz/3Ph
FLA ③, cooling only (A)--9.615.315.820.023.5
FLA ③, with heater & hum. (A)--13.322.823.327.531.0

Row Mount DX

ModelS-005RAS-007RAS-012RAS-017RAS-020RAS-025RAS-030RA
Mount typeRowRowRowRowRowRowRow
Cooling typeInverter DXInverter DXInverter DXInverter DXInverter DXInverter DXInverter DX
RefrigerantR134AR134AR134AR134AR134AR134AR134A
Total cooling (kW)5.67.612.817.621.225.131.1
SHR (%)100100100100100100100
Air volume (m³/h)2000225024004500492050005800
Fan typeECECECECECECEC
Reheat (kW)3.03.03.06.06.06.06.0
Heater typePTCPTCPTCPTCPTCPTCPTC
Humidification (kg/h)1.51.51.51.51.51.53
Humidifier typeElectrodeElectrodeElectrodeElectrodeElectrodeElectrodeElectrode
Filter ratingG4G4G4G4G4G4G4
Height (mm)2000200020002000200020002000
Depth (mm)1100110011001100110011001100
Width (mm)300300300300300300300
Weight (kg)210213233253258260320
Power input ①208-240V/50-60Hz/1-2Ph208-240V/50-60Hz/1-2Ph208-240V/50-60Hz/1-2Ph208-230V/50-60Hz/3Ph208-230V/50-60Hz/3Ph208-230V/50-60Hz/3Ph208-230V/50-60Hz/3Ph
FLA ①, cooling only (A)13.014.021.027.628.534.541.7
FLA ①, with heater & hum. (A)24.525.534.944.345.151.258.4
Power input ②380-415V/50-60Hz/3Ph380-415V/50-60Hz/3Ph380-415V/50-60Hz/3Ph380-415V/50-60Hz/3Ph380-415V/50-60Hz/3Ph380-415V/50-60Hz/3Ph380-415V/50-60Hz/3Ph
FLA ②, cooling only (A)--13.916.717.220.925.0
FLA ②, with heater & hum. (A)--19.725.826.330.034.1
Power input ③460V/60Hz/3Ph460V/60Hz/3Ph460V/60Hz/3Ph460V/60Hz/3Ph460V/60Hz/3Ph460V/60Hz/3Ph460V/60Hz/3Ph
FLA ③, cooling only (A)--12.614.414.818.021.5
FLA ③, with heater & hum. (A)--18.421.922.325.629.0
Standard outdoor unitKSF08ANKSF12ANKSF18ANKSF24ANKSF32ANKSF38ANKSF42AN
Outdoor unit qty1111111

WiseAir Room · 5.5–27.5 kW

Downflow unitW-005DAW-007DAW-012DAW-017DAW-020DAW-025DA
Upfront-flow unitW-005FAW-007FAW-012FAW-017FAW-020FAW-025FA
Mount typeRoomRoomRoomRoomRoomRoom
Cooling typeInverter DXInverter DXInverter DXInverter DXInverter DXInverter DX
RefrigerantR134AR134AR134AR134AR134AR134A
Cooling capacity (kW)5.57.512.517.521.227.5
Sensible capacity (kW)5.26.811.315.919.125
SHR (%)94.590.790.490.990.190.9
Air volume (m³/h)200022502850500062006700
Fan typeECECECECECEC
Heating capacity (kW)334666
Heating typePTCPTCPTCPTCPTCPTC
Humidification (kg/h)2.52.544.54.55
Humidifier typeElectrodeElectrodeElectrodeElectrodeElectrodeElectrode
Filter ratingG3G3G3G4G4G4
Weight (kg)118128178300318338
Width (mm)550550650750750850
Depth (mm)450450550700700700
Height (mm)175017501850190019001900
Power input ①208-240V/50-60Hz/1-2Ph208-240V/50-60Hz/1-2Ph208-230V/60Hz/3Ph208-230V/60Hz/3Ph208-230V/60Hz/3Ph208-230V/60Hz/3Ph
FLA ①, cooling only (A)13.714.723.130.531.438.7
FLA ①, with heat & hum. (A)25.326.330.547.248.055.3
Power input ②380-415V/50-60Hz/3Ph380-415V/50-60Hz/3Ph380-415V/50-60Hz/3Ph380-415V/50-60Hz/3Ph380-415V/50-60Hz/3Ph380-415V/50-60Hz/3Ph
FLA ②, cooling only (A)--12.716.817.321.3
FLA ②, with heat & hum. (A)--24.325.926.430.4
Power input ③460V/60Hz/3Ph460V/60Hz/3Ph460V/60Hz/3Ph460V/60Hz/3Ph460V/60Hz/3Ph460V/60Hz/3Ph
FLA ③, cooling only (A)--10.513.914.317.6
FLA ③, with heat & hum. (A)--20.021.421.825.1
Ref. pipe connection (mm)10/1210/1212/1616/1616/1616/22
Drain connection (mm)202020202020
Water in connection3/4"G3/4"G3/4"G3/4"G3/4"G3/4"G
Single/dual systemSingleSingleSingleSingleSingleSingle
Standard outdoor unitKSF08ANKSF12ANKSF18ANKSF24ANKSF24ANKSF32AN
Outdoor unit qty111111

WiseAir Room · 32.5–71.1 kW

Downflow unitW-030DAW-035DAW-045DAW-055DAW-065DAW-070DA
Upflow unitW-030UAW-035UAW-045UAW-055UAW-065UAW-070UA
Mount typeRoomRoomRoomRoomRoomRoom
Cooling typeInverter DXInverter DXInverter DXInverter DXInverter DXInverter DX
RefrigerantR134AR134AR134AR134AR134AR134A
Cooling capacity (kW)32.537.743.553.165.171.1
Sensible capacity (kW)29.33439.247.858.864
SHR (%)90.290.290.190.290.390.0
Air volume (m³/h)8325862010500124001665017240
Fan typeECECECECECEC
Heating capacity (kW)669999
Heating typePTCPTCPTCPTCPTCPTC
Humidification (kg/h)8810101010
Humidifier typeElectrodeElectrodeElectrodeElectrodeElectrodeElectrode
Filter ratingG4G4G4G4G4G4
Weight (kg)433438478568688718
Width (mm)112611261326132618261826
Depth (mm)990990990990990990
Height (mm)197519751975197519751975
Power input ①208-230V/60Hz/3Ph208-230V/60Hz/3Ph208-230V/60Hz/3Ph208-230V/60Hz/3Ph208-230V/60Hz/3Ph208-230V/60Hz/3Ph
FLA ①, cooling only (A)49.151.464.274.698.298.7
FLA ①, with heater & hum. (A)65.868.089.299.6123.2123.7
Power input ②380-415V/50-60Hz/3Ph380-415V/50-60Hz/3Ph380-415V/50-60Hz/3Ph380-415V/50-60Hz/3Ph380-415V/50-60Hz/3Ph380-415V/50-60Hz/3Ph
FLA ②, cooling only (A)27.128.335.441.254.154.4
FLA ②, with heater & hum. (A)36.237.449.154.967.868.1
Power input ③460V/60Hz/3Ph460V/60Hz/3Ph460V/60Hz/3Ph460V/60Hz/3Ph460V/60Hz/3Ph460V/60Hz/3Ph
FLA ③, cooling only (A)22.423.429.334.044.745.0
FLA ③, with heater & hum. (A)29.930.940.645.356.056.3
Pipe connection (mm)16/2216/2216/2216/2216/2216/22
Drain connection (mm)202020202020
Water in connection3/4"G3/4"G3/4"G3/4"G3/4"G3/4"G
Single/dual systemSingleSingleDualDualDualDual
Standard outdoor unitKSF38ANKSF52ANKSF32ANKSF32ANKSF38ANKSF52AN
Outdoor units112222
Notes
1. Cooling Capacity based on 28C/40%RH return air and 35C outdoor air.
2. The maximum working ambient temperature up to 55C.

ATTOM data centers at mission-critical sites

Deployments of ATTOM, the data center brand MMC supplies, installs and supports in Pakistan. Case studies published by ATTOM.

AgileMod containment data center for CPPA-G
Energy · Islamabad, Pakistan

AgileMod containment data center for CPPA-G

A dual-row, six-rack cold-aisle containment system with overhead cable trays and multi-factor access control for Pakistan's Central Power Purchasing Agency.

Read ATTOM case study
AgileCub data center for the Central Reserve Bank
Finance · El Salvador

AgileCub data center for the Central Reserve Bank

A high-security container data center with bullet-resistant protection, access control and redundant power, delivered on a shorter timeline with efficient cooling.

Read ATTOM case study
Tier III container data center for Mindanao State University
Education · Philippines

Tier III container data center for Mindanao State University

A containerised data center with redundant power, precision cooling and real-time monitoring, part of MSU's move to a smart campus.

Read ATTOM case study

RESOURCES

Cooling a data center in extreme heat?

Talk to our cooling experts to choose the right capacity and configuration for your site.

Cooling a data center in extreme heat?

Get Hot Climate Cooling from MMC

Tell us about your site and load. We will recommend the right configuration and send a detailed quote.

  • Authorised ATTOM partnerGenuine ATTOM products and warranty, supplied locally.
  • Site survey & designOur engineers size the cooling capacity for your heat load and space.
  • Installation & commissioningDelivery, installation and commissioning by MMC’s data center team.
  • Ongoing supportMaintenance and support from our Karachi head office.
Talk to our team

Precision Cooling for Hot Climates enquiry. We reply within one business day.

Or call +92 311 1555053

Plan with MMC

Data center cooling for hot climates

Data center cooling must account for outdoor design temperatures as well as IT loads. Evaluate equipment capacity under the conditions expected at the installation site.

Define the requirement

Share the location, outdoor equipment placement and peak IT load. Note dust exposure, restricted airflow and maintenance access.

Compare the delivery scope

Ask for performance at the stated design conditions. Review monitoring, resilience and servicing arrangements before agreeing the cooling solution.

Our reach

Countries we serve

  • Pakistan flagPakistan
  • USA flagUSA
  • Australia flagAustralia
  • Belgium flagBelgium
  • Paraguay flagParaguay
  • Denmark flagDenmark
  • UK flagUK
  • Afghanistan flagAfghanistan
  • Philippines flagPhilippines
  • Turkey flagTurkey
  • Thailand flagThailand
  • Canada flagCanada
  • Sweden flagSweden
  • Singapore flagSingapore
  • Colombia flagColombia
  • UAE flagUAE
  • New Zealand flagNew Zealand
  • Kyrgyzstan flagKyrgyzstan
  • France flagFrance
  • Switzerland flagSwitzerland
  • Tanzania flagTanzania
  • Uganda flagUganda
  • Tajikistan flagTajikistan
  • China flagChina
  • Italy flagItaly
  • Finland flagFinland
  • Qatar flagQatar
  • Zimbabwe flagZimbabwe
  • Saudi Arabia flagSaudi Arabia