U-position management host
Data aggregation, management, and upload
MMC PAKISTAN �� AgileAsset U-Position Asset Management System
The Asset Management System is designed for intelligent rack-level IT asset tracking in data centers and equipment rooms.
TALK TO MMC
Share your requirements, location and timeline. We��ll help you define a suitable solution and delivery scope.
[email protected]By using U-level asset management strips, electronic tags, and monitoring software, the system can identify the exact rack position of each device, monitor U-space usage in real time, and support fast automatic inventory checks. It helps operators reduce manual inspection work, prevent asset misplacement, improve rack space utilization, and maintain accurate asset records throughout the full equipment lifecycle. The system can also integrate with third-party monitoring or DCIM platforms, making it suitable for modern data centers that require precise, visualized, and efficient asset management.
Suited forThe product offers flexible and modular designs with magnetic mounting, making it easy to install and adapt to different cabinet types. Its compact size saves space and supports fast deployment in data centers, telecom rooms, and server cabinets.
The product uses magnetic mounting for quick installation and maintenance, while the contact-based tag design avoids wireless signal interference. Gold-plated contact points help prevent oxidation and ensure stable, reliable communication in daily operation.
Millisecond-level U-position identification enables real-time asset tracking and accurate asset status updates.
A web-based configuration platform supports remote setup, online configuration, and IP whitelist management for improved system security.
Supports stable operation in temperatures from -10°C to 50°C and humidity from 5% to 95% RH.
Automated millisecond-level asset inventory helps reduce manual workload, improve accuracy, and avoid human errors.
Supports third-party platform integration through HTTP northbound interface and Modbus RTU protocol interface.
Real-time U-position monitoring helps optimize rack space usage and improve overall data center space utilization.
Supports AC and DC dual power supply with wide-voltage input for flexible deployment.
A 47U rack-mounted U-position electronic tag consumes approximately 125 mA, supporting efficient plug-and-play deployment.
Real-time asset monitoring and data upload support full lifecycle management, including check-in, check-out, relocation, inventory, maintenance, decommissioning, and alarms.
Optional temperature and humidity asset tags provide high-precision monitoring with ±1°C temperature accuracy and ±5% humidity accuracy.
The U-position management host is equipped with four RJ45 serial ports that support both communication and power supply, as well as RS485 ring connection. If the third-party host does not support power supply for downstream modules, it can be powered through our dedicated switching power supply module.
Technical data from the ATTOM product brochure.
| Model | S80-A3-DDCU04-A01 | S80-A3-DDCU04-A02 |
|---|---|---|
| Processor / OS | ARM9 / RTOS | ARM9 / RTOS |
| Design lifetime | > 10 years | > 10 years |
| Uplink network | 1, 100M, HTTP | 1, 100M, HTTP |
| Downlink serial ports | 4 serial ports, RJ45; communication and power supply; supports RS485 loop connection | 4 serial ports, RJ45; communication and power supply |
| Asset strips | Up to 10 per serial port, 40 per host | Up to 4 per serial port, 8 per host |
| Accuracy | 100% | 100% |
| Response time | < 1000ms | < 1000ms |
| Data real-time | < 2000ms | < 2000ms |
| MTBF / MTTR | More than 50,000 hours / < 0.5 hours | More than 50,000 hours / < 0.5 hours |
| Power input | Two channels, AC 100-240V and DC 140-330V | DC9~16V |
| Power consumption | Less than 10W, excluding power for external supply | Less than 10W, excluding power for external supply |
| Operating temperature | -10 ~ 50 ℃ | -10 ~ 50 ℃ |
| Operating humidity | 5 to 95%, no condensation | 5 to 95%, no condensation |
| Size | 481 mm * 244 mm * 44.5 mm | 105mm (L) * 75mm (W) * 30mm (H) |
| Model | S80-A3-TMMR01-A01 |
|---|---|
| Managed U-position quantity | 40U - 52U |
| Indicator lights | 1 each for system and communication indicators |
| Fixed type | Magnetic attraction |
| Communication ports | 2 RJ45s |
| Communication protocol | Modbus RTU |
| Asset strip connection | TYPE-C |
| Power supply | DC12V |
| Operating temperature | -10 - 50℃ |
| Operating humidity | 5 - 95%, no condensation |
| Dimensions | 63*42.4*23mm |
| Model | S80-A3-DUCUxx-B01 | S80-A3-DUCUxx-B02 | S80-A3-DUHUxx-B01 | S80-A3-DUHUxx-B02 | S80-A3-DUHUxx-C01 |
|---|---|---|---|---|---|
| Temperature & humidity monitoring | - | - | 3 channels: upper, middle, lower | 3 channels: upper, middle, lower | 3 channels: upper, middle, lower |
| Precision | - | - | Temperature ±1℃, humidity ±5% | Temperature ±1℃, humidity ±5% | Temperature ±1℃, humidity ±5% |
| Indicator light | 1 blue-red dual-color light per U-position, 4 U-position statuses | 1 blue-red dual-color light per U-position, 4 U-position statuses | 1 blue-red dual-color light per U-position, 4 U-position statuses | 1 blue-red dual-color light per U-position, 4 U-position statuses | 1 blue light per U-position, 4 U-position states |
| Fixed method | Magnetic attraction | Magnetic attraction | Magnetic attraction | Magnetic attraction | Magnetic attraction |
| Label contact | Magnetic plus contact | Magnetic plus contact | Magnetic plus contact | Magnetic plus contact | Magnetic plus contact |
| Uplink serial port | 1 TYPE-C interface | 1 TYPE-C interface | 1 TYPE-C interface | 1 TYPE-C interface | 1 TYPE-C interface |
| Communication protocol | RS485 with the U-position detection interface module | RS485 with the U-position detection interface module | RS485 with the U-position detection interface module | RS485 with the U-position detection interface module | RS485 with the U-position detection interface module |
| Accuracy | 100% | 100% | 100% | 100% | 100% |
| Power | DC12V, powered by the interface module | DC12V, powered by the interface module | DC12V, powered by the interface module | DC12V, powered by the interface module | DC12V, powered by the interface module |
| Size (per U-position) | 46.2mm*20mm*8mm | 44.5mm*20mm*8mm | 46.2mm*20mm*8mm | 44.5mm*20mm*8mm | 44.5mm*20mm*8mm |
| Selection | 42U / 47U / 48U / 52U cabinets | 42U / 47U / 48U / 52U cabinets | 42U / 47U / 48U / 52U cabinets | 42U / 47U / 48U / 52U cabinets | 42U / 47U / 48U / 52U; splicing with 5U/6U strips |
| Model | S80-A3-LUCU01-B01 |
|---|---|
| Reading method | Two-wire system |
| Tag ID | 8 bits, read-only after factory shipment |
| Connection method | Magnetic attraction + contact |
| QR code | 10*10mm, content is the ID of the electronic tag |
| Installation method | Asset strip end: magnetic attraction; asset end: adhesive |
| Power supply | 3.3~5V |
| Operating temperature | -10~50℃ |
| Operating humidity | 5~95%, no condensation |
| Dimensions | Diameter 17mm, thickness 8mm |
| Connection rope | 200mm, 400mm optional |
| Model | S80-A3-01RSCD-A01 |
|---|---|
| Interface | Micro USB (comes with a Micro USB cable) |
| Power supply | USB power |
| Communications | Contact, two-wire |
| Size | 50*68*18 (mm) |
| Operating temperature | -10 ~ 50 ℃ |
| Operating humidity | 5 to 95%, no condensation |
| Model | S80-A3-PSU16-A01 |
|---|---|
| Power input | 1 AC/DC input, 100 to 240VAC / 140 to 330VDC |
| Power output | 16 DC outputs, total load capacity 12V@8A |
| Indicator light | Each output has a working indicator light |
| Wiring | RJ45 terminals, wire sequence matched to the U-position detection interface module |
| Protection | Each output port supports reverse connection protection |
| Size | 481mm*244mm*44.5mm, 1U rack-mounted |
Deployments of ATTOM, the data center brand MMC supplies, installs and supports in Pakistan. Case studies published by ATTOM.
Plan with MMC
An asset management system for a data center should connect equipment records to physical locations and operational ownership. Review AgileAsset against your rack inventory and asset processes.
Share cabinet counts, asset records, location conventions and move/add/change workflows. Identify existing monitoring or service-management integrations.
Agree on record migration, asset identification and ongoing update responsibilities. Validate reporting and location accuracy as part of acceptance.
Our reach
Pakistan
USA
Australia
Belgium
Paraguay
Denmark
UK
Afghanistan
Philippines
Turkey
Thailand
Canada
Sweden
Singapore
Colombia
UAE
New Zealand
Kyrgyzstan
France
Switzerland
Tanzania
Uganda
Tajikistan
China
Italy
Finland
Qatar
Zimbabwe
Saudi Arabia