MMC PAKISTAN �� AgilePower UPS – Uninterrupted Power Supply

Agile Power – UPS Uninterrupted Power Supply

Full range of AgilePower UPS is designed in an on-line double conversion system and DSP control technology to ensure better output voltage conditions, power quality, and performance at all times, with extreme efficiency, ease of use, and reliability to provide superior protection for your critical infrastructure.

TALK TO MMC

Plan your next step with our team

Share your requirements, location and timeline. We��ll help you define a suitable solution and delivery scope.

[email protected]

Talk to our team

AgilePower UPS enquiry. We reply within one business day.
Or call +92 311 1555053
1 – 600 kVA
UPS capacity range
Up to 1.0
Output power factor
60 kVA in 4U
Rack mount UPS
1C – 4C
Lithium discharge current
ATTOM AgilePower UPS range

Uninterrupted Power Supply

With the matching external battery system provides scalable battery runtime to maintain business operations without downtime. It is the best choice for all types of backup power needs from small edge data centers to large data centers.

Applications
Small Edge Data CentersLarge Data CentersRack to Room MountingIEC & America Input Power

Key Advantages & System Highlights

Modularity

Rack oriented modularity design maximize the scalability and flexibility, brings predictable management to the application.

Reliability

The verified reliability backup by trusted industry capability, and long history experience.

Efficiency

High efficiency design generating less heat and distributing more power. Saving OPEX and improving performance.

Flexibility

All types of power modules and capabilities make it flexible for diverse global application, from rack to room mounting type, and IEC to America input power type.

All Types of UPS Series

ATTOM Rack Mount UPS

Rack Mount UPS

1-60kVA

The standard 19” rack mount design makes it easy to install in a variety of racks, similar to the appearance of IT equipment.

  1. 1High-performance MCU control for higher reliability.
  2. 2Output PF: 0.8-1.0
  3. 3Ultra-wide voltage input range for harsh grid environments.
  4. 4Multiple protection functions such as overload, short circuit, over voltage, under voltage and bypass.
  5. 5Intelligent battery management features to extend battery life.
  6. 6Online double-conversion UPS, support multiple voltage specifications: 220-240/380-415V.
  7. 7Wide capacity range up to 60k in 4U space saving dimension.
  8. 8Powerful network management function, optional SNMP, providing a variety of monitoring methods. Standard RS232 interface.
Request pricing
ATTOM Rack Modular UPS

Rack Modular UPS

60-200kVA

Modular UPS is a hot-swappable, highly scalable online dual-conversion product that uses advanced IGBT three-level conversion and dual DSP control technology for high ease of use and reliability.

  1. 1Compatible with 19” standard rack cabinet, convenient to be integrated into server cabinet.
  2. 2Output PF: 1
  3. 34.3” touch color LCD, more information displayed and easier for customer to operate.
  4. 420/25/30/50kVA power module in 2U/3U height, saving great amount of space.
  5. 5System can intelligently shut down some power modules to increase total load rate, achieving higher efficiency.
  6. 6Modular design, support for hot swap.
Request pricing
ATTOM Floor Modular UPS

Floor Modular UPS

150-600kVA

The modular UPS designed to protect any critical load for medium and larger data center achieving maximum availability. This series feature the latest technology of 3-level technology and PFC input control, which guarantees high efficiency of 95% and ultra-reliability, making it an excellent choice for medium and larger facilities.

  1. 1Each power module has an independent LCD, gives users’ direct overview of status data and alarms in real time.
  2. 2Output PF: 1.0
  3. 37”/10’’ touch color LCD, more information displayed and easier for customer to operate.
  4. 425~100kVA high power module, saving great amount of space.
  5. 5System can intelligently shut down some power modules to increase total load rate, achieving higher efficiency.
  6. 6Modular design, support for hot swap.
Request pricing
ATTOM Tower Type UPS

Tower Type UPS

20-200kVA

Designed in small footprints with DSP technology and active input power factor correction design to ensure better output voltage conditions, power quality and power performance at all times.

  1. 1True double-conversion.
  2. 2DSP technology guarantees high performance.
  3. 3High power factor: 0.9-1.0
  4. 4ECO mode operation for energy saving (ECO).
  5. 5Emergency power off function (EPO).
  6. 6SNMP+USB+RS-232 multiple communications.
  7. 7Maintenance bypass available.
  8. 8Optional parallel operation up to 4 units.
  9. 97" touch LCD panel.
Request pricing

Rack Oriented System

  • Standard 19” rack mount design makes it easy to install in a variety of racks, similar to the appearance of IT equipment.
  • Wide capacity range up to 60kVA in 4U space saving dimension.
  • True Online double-conversion UPS, Support multiple voltage specifications: 220-240/380-415V.
  • Output PF up to 1.0
  • Multiple protection functions such as overload, short circuit, over voltage, under voltage and bypass.
  • Parallel redundancy available up to 3 units, increase power capacity safety and availability.
  • Powerful network management function, support standard RS232 interface optional SNMP.
ATTOM rack oriented UPS system
ATTOM modular UPS systems

Multiple Modular System

  • Highly scalable online dual-conversion product that uses advanced dual DSP control technology for high ease of use and reliability.
  • Compatible with 19” standard rack cabinet, convenient to be integrated into server cabinet.
  • 10/15/25kVA power module in 2U/3U height, saving great amount of space.
  • Unity output power factor up to 1.0
  • High overload capacity supports Load≤110%, 60min; ≤125%, 10min; ≤150%, 1min.
  • Hot swappable modular design, easy of installation and maintenance.
  • 7” touch color LCD, more information displayed and easier for customer to operate.

Full Lithium Battery Compatibility

Lithium Iron Phosphate Battery System

  • Designed for all types UPS, no need complex protocol coupling.
  • Intelligent BMS system for reliable working, alarm reporting, and remote monitoring.
  • Safety by full protection including over-current, over-charge, over-discharge, and short-circuit, etc.
  • Rear wiring connections suitable for rack deployment.
  • 1C – 4C discharge current can match the supported power loads.
ATTOM lithium battery system for UPS

Technical data

Technical data from the ATTOM product brochure.

Rack Mount UPS · IEC

ModelU-001R11HU-002R11HU-003R11HU-006R11HU-010R11HU-010R33HU-015R33HU-020R33HU-030R33HU-040R33HU-060R33H
Capacity1kVA2kVA3kVA6kVA10kVA10kVA15kVA20kVA30kVA40kVA60kVA
Parallel---33333333
Input phase11111333333
Input voltage208/220/230/240Vac208/220/230/240Vac208/220/230/240Vac208/220/230/240Vac208/220/230/240Vac380/400/415Vac380/400/415Vac380/400/415Vac380/400/415Vac380/400/415Vac380/400/415Vac
Acceptable voltage range160-300Vac160-300Vac160-300Vac110-300Vac110-300Vac208-478Vac208-478Vac208-478Vac208-478Vac208-478Vac208-478Vac
Frequency range40-70Hz40-70Hz40-70Hz46-54Hz or 56-64Hz46-54Hz or 56-64Hz40-70Hz40-70Hz40-70Hz40-70Hz40-70Hz40-70Hz
Input power factor≧0.99≧0.99≧0.99≧0.99≧0.99≧0.99≧0.99≧0.99≧0.99≧0.99≧0.99
Output phase11111333333
Output voltage208/220/230/240Vac208/220/230/240Vac208/220/230/240Vac208/220/230/240Vac208/220/230/240Vac380/400/415Vac380/400/415Vac380/400/415Vac380/400/415Vac380/400/415Vac380/400/415Vac
Output power factor0.80.80.811111111
Voltage regulation±1%±1%±1%±1%±1%±1%±1%±1%±1%±1%±1%
Harmonic distortion≤3% (100% linear load)≤3% (100% linear load)≤3% (100% linear load)≤3% (100% linear load)≤3% (100% linear load)≤1% (100% linear load)≤1% (100% linear load)≤1% (100% linear load)≤1% (100% linear load)≤1% (100% linear load)≤1% (100% linear load)
Efficiency, AC mode89%90%90%94%94%95.5%95.5%95.5%95.5%95.5%95.5%
Battery voltage24/36Vdc48/72Vdc72/96Vdc240Vdc240Vdc384-480Vdc384-480Vdc384-480Vdc384-480Vdc384-480Vdc384-480Vdc
Weight9kg12kg14kg15kg18kg27kg30kg30kg32kg40kg45kg
Operational condition0-40C, 0-95%RH (no condensing)0-40C, 0-95%RH (no condensing)0-40C, 0-95%RH (no condensing)0-40C, 0-95%RH (no condensing)0-40C, 0-95%RH (no condensing)0-40C, 0-95%RH (no condensing)0-40C, 0-95%RH (no condensing)0-40C, 0-95%RH (no condensing)0-40C, 0-95%RH (no condensing)0-40C, 0-95%RH (no condensing)0-40C, 0-95%RH (no condensing)
MonitoringRS232, Optional SNMPRS232, Optional SNMPRS232, Optional SNMPRS232, Optional SNMPRS232, Optional SNMPRS232, Optional SNMPRS232, Optional SNMPRS232, Optional SNMPRS232, Optional SNMPRS232, Optional SNMPRS232, Optional SNMP
Notes
  1. Dimensions (W*D*H mm) across the series: 310*438*88 (2U), 438*410*88 (2U), 438*600*88 (2U), 438*680*133 (3U) and 438*797*176 (4U).

ATTOM data centers at mission-critical sites

Deployments of ATTOM, the data center brand MMC supplies, installs and supports in Pakistan. Case studies published by ATTOM.

CPPA-G office building in Islamabad
ENERGY · ISLAMABAD, PAKISTAN

AgileMod containment data center for CPPA-G

A dual-row, six-rack cold-aisle containment system with overhead cable trays and multi-factor access control for Pakistan’s Central Power Purchasing Agency.

Read the case study →
Central Reserve Bank of El Salvador building sign
FINANCE · EL SALVADOR

AgileCub data center for the Central Reserve Bank

A high-security container data center with bullet-resistant protection, access control and redundant power, delivered on a shorter timeline with efficient cooling.

Read the case study →
ATTOM AgileCub container data center being delivered to Mindanao State University
EDUCATION · PHILIPPINES

Tier III container data center for Mindanao State University

A containerised data center with redundant power, precision cooling and real-time monitoring, part of MSU’s move to a smart campus.

Read the case study →

RESOURCES

Product Brochure DownloadAttom AgilePower UPS BrochureDownload PDFWhite Paper DownloadWhen Micro Data Center Meets Edge ComputingDownload PDF

Plan your data center power system?

The Mission Critical Power Optimized for Your Data Center Projects. Talk to our power experts to size the right system for your load and runtime.

Get a free quote →+92 311 1555053

Plan with MMC

Online UPS sizing and runtime

An online UPS configuration should match the protected load and required ride-through time. Review AgilePower UPS capacity, battery arrangements and maintenance requirements together.

Define the requirement

Provide load measurements, equipment power factors, supply details and desired runtime. Identify future expansion and any generator integration.

Compare the delivery scope

Verify the proposed runtime at the stated load and battery configuration. Agree on bypass arrangements, installation, testing and maintenance access.

Our reach

Countries we serve

  • Pakistan flagPakistan
  • USA flagUSA
  • Australia flagAustralia
  • Belgium flagBelgium
  • Paraguay flagParaguay
  • Denmark flagDenmark
  • UK flagUK
  • Afghanistan flagAfghanistan
  • Philippines flagPhilippines
  • Turkey flagTurkey
  • Thailand flagThailand
  • Canada flagCanada
  • Sweden flagSweden
  • Singapore flagSingapore
  • Colombia flagColombia
  • UAE flagUAE
  • New Zealand flagNew Zealand
  • Kyrgyzstan flagKyrgyzstan
  • France flagFrance
  • Switzerland flagSwitzerland
  • Tanzania flagTanzania
  • Uganda flagUganda
  • Tajikistan flagTajikistan
  • China flagChina
  • Italy flagItaly
  • Finland flagFinland
  • Qatar flagQatar
  • Zimbabwe flagZimbabwe
  • Saudi Arabia flagSaudi Arabia